Influence of Weak Stories on the Seismic Performance of Steel Frame Structures
DOI: https://doi.org/10.62517/jes.202602408
Author(s)
Chengang Liu, Hua Jiang*
Affiliation(s)
School of Civil Engineering, Nanning College of Technology, Guilin, Guangxi, China
*Corresponding Author
Abstract
In steel frame structures, a weak story is a level at which lateral stiffness or shear strength drops relative to adjacent levels, so that inelastic deformation concentrates there under strong ground motion. This paper examines how such a story influences global seismic performance and how the effect can be controlled. The formation of a weak story in steel frames is traced to three sources: an abrupt change in lateral stiffness, an abrupt change in story shear strength, and a non-uniform distribution of gravity load that alters the demand pattern. Their consequences are analysed in terms of inter-story drift concentration, reduction of collapse margin, and the shift of the plastic mechanism from a distributed beam-hinge pattern to a localized column-hinge pattern. Four control measures are compared, namely rocking cores and strongbacks, brace retrofitting, damping wall panels, and connection detailing, and their applicability is discussed against frame height, opening requirements, and construction constraints. The analysis indicates that the influence of a weak story depends less on the magnitude of the stiffness drop than on the degree of drift concentration it produces, and that control measures should be selected by their ability to redistribute drift rather than by their ability to increase local strength.
Keywords
Steel Frame Structure; Weak Story; Inter-Story Drift; Collapse Margin; Seismic Control
References
[1] Aghagholizadeh M. Weak-Story Mitigation and Drift Redistribution in Moment-Resisting Frames Using Stepping Rocking Walls. Earthquake Engineering and Structural Dynamics, 2026, 55(11):2760-2780.
[2] Wu S, Wang N, Cao Y Q, Feng X M, Chen J W. Uniform story drift optimization seismic design of steel frame structures. Journal of Building Engineering, 2025, 100:111747.
[3] Qu B, Sanchez-Zamora F, Pollino M. Mitigation of inter-story drift concentration in multi-story steel Concentrically Braced Frames through implementation of Rocking Cores. Engineering Structures, 2014, 70:208-217.
[4] Lin J L, Kek M K, Tsai K C. Stiffness configuration of strongbacks to mitigate inter-story drift concentration in buildings. Engineering Structures, 2019, 199:109615.
[5] Yamada S, Miyazawa H, Iyama J. Seismic performance of weak-beam-type steel low-to-middle-rise moment-resisting frame determined by local buckling of square hollow section columns. Thin-Walled Structures, 2024, 195:111359.
[6] Dowden D M, Baker A M. Seismic performance and collapse assessment of a steel boundary frame with non-gapping beam-to-column rocking connections with buckling-restrained brace structural fuses. Journal of Constructional Steel Research, 2024, 218:108705.
[7] Zhang C, Wu J, Huang W Y, Wang H, Gao J Z. Experimental and numerical study on seismic performance of semi-rigid steel frame infilled with prefabricated damping wall panels. Engineering Structures, 2021, 246:113056.
[8] Zhang Y T, He Z. Acceptable values of collapse margin ratio with different confidence levels. Structural Safety, 2020, 84:101938.
[9] Tantely J S, Zheng H. Seismic collapse margin of steel frame structures with symmetrically placed concentric braces. International Journal of Steel Structures, 2017, 17(3):969-982.
[10] Zahrai S M, Mousavi S A. Cable-pulley brace to improve story drift distribution of MRFs with large openings. Steel and Composite Structures, 2016, 21(4):863-882.
[11] Noruzvand M, Mohebbi M, Shakeri K. Performance-based seismic design of low-rise steel moment-resisting frames targeting collapse fragility curve. Structures, 2024, 70:107630.
[12] Das G, Deb S K. Seismic performance evaluation of a steel braced frame retrofitted using novel SC-SBRBs. Journal of Constructional Steel Research, 2026, 242:110373.
[13] Zhang P, Wang S P, Zhang S N. Optimized prediction of peak floor acceleration, peak inter-story drift ratio, and residual inter-story drift ratio in steel moment-resisting frames using innovative techniques. Soil Dynamics and Earthquake Engineering, 2026, 204:110189.
[14] Zhang H, Cui L, Wang S L. Anti-Progressive Collapse Performance of Fully Bolted Steel Frame Structure Connections Based on Performance Improvement. International Journal of Steel Structures, 2024, 24(1):201-213.